The Artfiles New Media GmbH data center at Wendenstraße 408 in Hamburg was completed in 2011. In total, it offers space for around 120 cabinets, spread across two completely separate fire compartments. It has been fully expanded since 2016.
We use Rittal racks in the W408 data center. Cold aisle containment is installed for all racks to ensure optimal climate control.
The power supply is provided by a dedicated transformer station (10 kV to 400 V), with expansion space available. In the event of a power supply failure, a diesel generator with a peak output of 690 kVA is available. Several UPS systems are available for the start-up phase of the unit, which usually takes less than 60 seconds. The generator is preheated around the clock, and the UPS systems can ensure the power supply for up to 10 minutes at maximum capacity. Both the UPS and the air conditioning system are fully redundant.
The power supply in the area is provided via four different main lines and fuses, enabling us to achieve a very high degree of redundancy down to the individual rack level. The space is designed to provide and dissipate 5,000 watts per rack, including air conditioning and cooling.
The data center is equipped with an Inergen gas fire suppression system. In addition to smoke detectors, humidity sensors are installed in the floor and air pressure gauges in the cold aisles to ensure trouble-free operation and enable immediate response in the event of malfunctions.
The access system is multi-level and secured by alarm and video surveillance. Access requires both a badge card with PIN entry and biometric authentication using a palm vein scanner. Motion detectors and cameras are installed throughout as part of the security system.
Of course, our data center is powered by 100% renewable energy. You can find more information about sustainability here: Sustainability at the Artfiles data center
Virtual Tour of the W408 Data Center
Of course, we would also be happy to show you our Hamburg data center directly on site. Just contact us to arrange an appointment.
Entrance Area to Data Center W408
Emergency Generator and Dry Cooler
Airlock to the data center; the door on the right leads to the fire extinguishing room.
Card Reader in the Interlock Room
Access Corridor to Colo1 with Small Work Area
Cold Aisle Rack Row in Colo1
Cold Aisle Row Interior View
View Through Two Cold Aisles
Part of the Colo1 Area with Two Cold Aisles
Cold Aisle Rack Row in Colo1
Part of the Cooling System and a Workstation in Colo1
Entrance and Ramp to Colo2
Rack Row and Customer Lockers in Colo2
View through the rows of cold aisles in Colo2
View of the Rack Rows from Above
Socomec UPS and Workstation in Colo2
A subsystem of the extinguishing system
Extinguishing agent gas cylinders in the fire extinguishing room
Next
Previous
/img/images/slideshow/w408/thumbnails/W408-10.jpg
/img/images/slideshow/w408/thumbnails/W408-01.jpg
/img/images/slideshow/w408/thumbnails/W408-02.jpg
/img/images/slideshow/w408/thumbnails/W408-03.jpg
/img/images/slideshow/w408/thumbnails/W408-04.jpg
/img/images/slideshow/w408/thumbnails/W408-05.jpg
/img/images/slideshow/w408/thumbnails/W408-06.jpg
/img/images/slideshow/w408/thumbnails/W408-07.jpg
/img/images/slideshow/w408/thumbnails/W408-08.jpg
/img/images/slideshow/w408/thumbnails/W408-09.jpg
/img/images/slideshow/w408/thumbnails/W408-10.jpg
/img/images/slideshow/w408/thumbnails/W408-11.jpg
/img/images/slideshow/w408/thumbnails/W408-12.jpg
/img/images/slideshow/w408/thumbnails/W408-13.jpg
/img/images/slideshow/w408/thumbnails/W408-14.jpg
/img/images/slideshow/w408/thumbnails/W408-15.jpg
/img/images/slideshow/w408/thumbnails/W408-16.jpg
/img/images/slideshow/w408/thumbnails/W408-17.jpg
/img/images/slideshow/w408/thumbnails/W408-18.jpg
/img/images/slideshow/w408/thumbnails/W408-19.jpg
/img/images/slideshow/w408/thumbnails/W408-20.jpg
/img/images/slideshow/w408/thumbnails/W408-21.jpg
/img/images/slideshow/w408/thumbnails/W408-22.jpg
/img/images/slideshow/w408/thumbnails/W408-23.jpg
/img/images/slideshow/w408/thumbnails/W408-24.jpg
/img/images/slideshow/w408/thumbnails/W408-25.jpg
/img/images/slideshow/w408/thumbnails/W408-26.jpg
Here you can download the technical data for the various Artfiles locations as a PDF. If you have any further questions, please contact our sales department:
Further Information About Our Services
Network Connectivity
Our external connectivity is constantly being expanded and technically enhanced.
Sustainability at Artfiles
Learn what we do to provide our services in the most environmentally friendly way possible.
Our Locations
Our Data Center Locations in Hamburg and abroad.
Previous
Next
-
Network Connectivity
Our external connectivity is constantly being expanded and technically enhanced.
-
Sustainability at Artfiles
Learn what we do to provide our services in the most environmentally friendly way possible.
-
Our Locations
Our Data Center Locations in Hamburg and abroad.